Nortel Networks CVX 600 Switch User Manual


 
Replacing Modules and Filler Panels
3-6 296-1011-202 Rel. 5.0, Doc. Rev. 02.01
CVX 600 Hardware Installation Guide
Installing a Rear Filler Panel
To install a rear filler panel, follow these steps:
Note: SCC fillers must be used for slot 5 or 6, adjacent to a single
SCC-LTM. All other slots use a MAC/DAC filler. The fillers look
identical except for the location of the screws. The installation and
removal procedures are the same for both types of fillers.
Step Action
1 Insert the filler panel into the empty slot.
2 Use a 1/4-inch flat-tip screwdriver to tighten the screws to 5 in-lb by turning
them clockwise.
SCC-LTM Filler
MAC/DAC-LTM Filler
CVX-0276A
CVX-0212A
AC PM 1
AC PM 2