Replacing Modules and Filler Panels
296-1011-202 Rel. 5.0, Doc. Rev. 02.01 3-21
Replacing CVX 600 Components
Replacing Other Service Modules
The MACs and DAC-SMs provide the processing capabilities for the
rear-installed LTMs. When you remove an online service module, the CVX 600
redirects processing to an adjacent secondary module that uses the same LTM.
These service modules can occupy chassis slots 1 to 4.
Replacement Procedure
The procedure for replacing these service modules is the same as the procedure
for replacing the SCC-SM.
Reference
See the CVX Multi-Service Access Switch Product Description for information on
where to position the modules
.
Caution: Do not install E1-DAC and DS1-DAC cards in the same
chassis. Because the CVX switch synchronizes to one external clock, a
CVX switch that contains both E1-DAC and DS1-DAC cards will not
function properly, and is not supported.