Nortel Networks CVX 600 Switch User Manual


 
Connecting Alarms
2-4 296-1011-202 Rel. 5.0, Doc. Rev. 02.01
CVX 600 Hardware Installation Guide
Sonet/SDH S
Trace Mismatch
Minor The Section Trace string in the received frame does
not match the configured value in the
StraceStringExpect attribute.
Sonet/SDH P
Trace Mismatch
Minor The Path Trace string in the received frame does not
match the configured value in the
PtraceStringExpect attribute.
Sonet/SDH LOS
Alarm Clear
Major The LOS alarm condition is cleared.
Sonet/SDH LOF
Alarm Clear
Major The LOF alarm condition is cleared.
APS Live Minor The designated optical interface is up and can
received calls.
APS Standby Minor The designated optical interface is up, but is in
standby mode.
APS Down Minor The designated optical interface is down.
ATM Red Alarm Major The specified link port has a critical alarm, such as
the absence of a line signal.
ATM Yellow
Alarm
Major The specified link port has an informational alarm.
ATM Alarm
Clear
Major The specified link port alarms are cleared.
ATM Marker
Port Up
Minor The STIC Marker port is up.
ATM Marker
Port Down
Minor The STIC Marker port is down.
ATM Interface
Up
Minor The ATM interface is up.
ATM Interface
Down
Minor The ATM interface is down.
ATM Logical
Interface Up
Minor The logical interface on the ATM interface is up.
ATM Logical
Interface
Minor The logical interface on the ATM interface is down.
ATM ILMI
Enabled
Minor The ILMI interface is up.
ATM ILMI
Disabled
Minor The ILMI interface is down.
Alarm Type Severity Description