Nortel Networks CVX 600 Switch User Manual


 
Applying Power to the CVX 600
2-42 296-1011-202 Rel. 5.0, Doc. Rev. 02.01
CVX 600 Hardware Installation Guide
Applying Power to the CVX 600
Procedure
To apply power to the CVX 600, follow these steps:
Step Action
1 Ensure that you have connected all power cables to the appropriate terminals.
2 Ensure that you have installed the clear protective cover over the power cable
terminals.
3 Ensure that you have inserted the flash memory card in PCMCIA slot 1 on the
SCC (the upper SCC, if using master and redundant SCCs).
4 Ensure that both switches on the circuit breakers (PDUs) are off.
5 Apply power from the power source.
6 Ensure that the red LEDs on both PDUs are on. If they are, turn the switches
on both circuit breakers (PDUs) on. If the LEDs are not on, check all power
connections.
Fans
1
2
3
4
5
6
CVX 6oo
BIP
BIP
Yellow Red
1
2
3
4
5
6
7
8
9
10
11
12
Power
Good
Failed
Redun
PDU 2
PDU 1
ESD
Jack
O
I
O
I
CVX-0202B
Circuit breaker (PDU) switches
Modem/ISDN
Pwr
Good
Fail
Redun
Modem/ISDN
Pwr
Good
Fail
Redun
Modem/ISDN
Pwr
Good
Fail
Redun
DAC DS1x24
Pwr
Good
Fail
Redun
YEL
RED
YEL
RED
3
1
10
11
24
2
12
22
23
21
19
20
18
16
17
15
13
14
9
7
8
6
4
5
System
Pwr
Good
Fail
Redun
10/100 Enet
3
2
1
HSSI
RESET
PCMCIA
1
2
System
Pwr
Good
Fail
Redun
10/100 Enet
3
2
1
HSSI
RESET
PCMCIA
1
2