Connecting Alarms
296-1011-202 Rel. 5.0, Doc. Rev. 02.01 2-5
Chassis Connections
Reference
For pinout assignments, see Appendix A, “Technical Specifications.”
ATM PVPC
PVCC Up
Minor The PVPC/PVCC has been successfully created.
ATM PVPC
PVCC
Minor The PVPC/PVCC is down.
ATM APS
Switchover
Minor A link failure caused the PHY driver to turn on the
redundant PHY.
Sonet/SDH
Alarm Sdber
Major The specified STM-1 is in Signal Degrade Bit Error
Rate alarm. The value set in the
SigDegradeThreshold attribute for this line has
been exceeded.
Sonet/SDH
Alarm Sfber
Major The specified STM-1 is in Signal Failure Bit Error
Rate alarm. The value set in the
SigFailureThreshold attribute for this line has been
exceeded.
Sonet/SDH
Alarm Sdber
Clear
Major The specified STM-1 is not in Signal Degrade Bit
Error Rate alarm. The Signal Degrade Bit Error Rate
is now below the SigDegradeThreshold value set in
the configuration.
Sonet/SDH
Alarm Sfber
Clear
Major The specified STM-1 is not in Signal Failure Bit Error
Rate alarm. The Signal Failure Bit Error Rate is now
below the SigFailureThreshold value set in the
configuration.
Alarm Type Severity Description