Paradyne 3600 Computer Drive User Manual


 
Configuration Scenarios
D-93610-A2-GB41-60 March 1999
Configuration Options
Set the central-site bridge configuration options as
follows (Configuration Worksheet for Bridge Mode)
MUX – Setup
MUX Funct: CBrdg
Bridge Rate: =DSU
Brdg Timing: Int
Share DevA: Enab
Lowest Port#: DCE
# Ports in Gp: 4
Port Cntrl: Host
Share DevB: Disab
Prt2 through Prt4 (Prt5 and Prt6 N/A)
RTS Cntrl: DTE
Elast Stor: Enab
RTS/CTS Del: 0
DTR Alarm: Disab
DSU
Rate(Kbps): 9.6
TxClkSource: DDS
Msg Clamp: Enab
TxElastStor: Disab
AggrSwitch: Disab
Diag – DSU
Diag Type: Mixed
Disr Type: 3600e
Diag – Gen
Position: Cntrl
LinkConfig: M-Pt
Trib TimOut: enter amount of time
Gen
DTE Port: EIA232
Set configuration options for automatic partial backup
using the DBM-V as follows (Configuration Worksheet for
Basic (DBM-V, DBM-S, or DBM-D) Mode):
Diag – DBM
Diag Type: Disr
RemoteDiag: Enhan
Diag – Gen
Position: Cntrl
LinkConfig: M-Pt
M-Pt SymPrt: Disab
DBM
Rate(Kbps): 9.6
PrtSp(Kbps): 9.6
TxClkSource: Ext
CarrLossDisc: Yes
Auto Retrain: Yes
Single Rate: Yes
AutoAnswer: Enab
Call Setup: Pswrd
RxPwd: enter received password
TxPwd: enter transmit password
V.13 Signl: Enab
Primary Core: Yes
DTRCallCon: Orig
EchoCancel: Disab
Gen
DTE Port: EIA232
RTS Cntrl: FrcOn
CTS Cntrl: Std
AntiStream: Disab
LSD Lead: Std
CTS Lead: Std
DSR FrcOn: Enab
DSR on Tst: Enab
Circ Assur: Disab
LL by DTE: Disab
RL by DTE: Disab
DTR Alarm: Disab
Bkup
Auto Bckup: Disab
BckupOnCMI: Disab
AutoRestor: Disab
Backup Dir: enter
Dir number (1 to 10)