Model 3610 Installation
2-53610-A2-GB41-60 March 1999
3. Disconnect the keypad flat cable from the DSU
circuit card by squeezing the latches on each side
of the cable and gently pulling up (refer to
Figure 2-4).
4. Disconnect the LCD flat cable by gently working
the cable, not the connector, free of its connector.
Be careful not to bend any of the cable pins.
5. Disconnect the TDM/MCMP flat cable.
6. Unscrew the three screws that hold the DSU
circuit card in place.
7. Remove the DSU from the base. Carefully lift the
DSU up until its connectors are free of the rear
panel. Set the DSU on a clean ESD (anti-static)
workpad.
Figure 2-4. Assembling/Disassembling the TDM or MCMP