Paradyne 3600 Computer Drive User Manual


 
COMSPHERE 3600 Series Data Service Units
D-32 March 1999 3610-A2-GB41-60
Prt2 and Prt4 (Prt6 N/A)
AsyncSync: Disab for control;
N/A for tributary
TxCarrSel: Const for control; N/A for tributary
RxCarrSel: Const for control; N/A for tributary
Elast Stor: Disab for control; N/A for tributary
PrtSp – DBM
Prt1: N/A for control; 7.2 for tributary
Prt2: N/A for control; Disab for tributary
Prt3: N/A for control; 4.8 for tributary
Prt4 through Prt6: N/A for control;
Disab for tributary
PrtSp – Chan
Prt1: A
Prt2: A for control; None for tributary
Prt3: B Prt4: B for control; None for tributary
Prt5: C
Prt6: None
DSU
Rate(Kbps): 56
TxClkSource: DDS
AggrSwitch: Disab
Diag – DSU
Diag Type: NonD
2nd Ch(bps): 400 for control and tributary
Disr Type: 3600e
Diag – Gen
Position: Cntrl for control; Trib for tributary
LinkConfig: M-Pt
DBM
Rate(Kbps): N/A for control; 14.4 for tributary
TxClkSource: N/A for control; RXC for tributary
CarrLossDisc: N/A for control; Yes for tributary
Auto Retrain: N/A for control; Yes for tributary
Single Rate: N/A for control; Yes for tributary
AutoAnswer: Enab
Call Setup: Pswrd
RxPwd: enter received password
TxPwd: enter transmit password
Primary Core: No for control and tributary
DTRCallCon: N/A for control; Disab for tributary
Gen
DTE Port: EIA232
RTS Control: FrcOn
Bkup
Auto Bckup: N/A for control; Enab for tributary
Backup Dir: N/A for control;
enter Dir number (1 to 10) for tributary
BckupOnCMI: N/A for control;
Enab for tributary
AutoRestor: N/A for control; Enab for tributary
NtwkTimOut: N/A for control;
enter amount of time for tributary
RestorTimOut: N/A for control;
enter amount of time for tributary
TriesTimOut: N/A for control;
enter amount of time for tributary