Paradyne 3600 Computer Drive User Manual


 
COMSPHERE 3600 Series Data Service Units
D-12 March 1999 3610-A2-GB41-60
To end the backup session via the NMS, issue
disconnect commands to the control DSU and all its
DBM-Ss. (The NMS restores all control and tributary
DSUs to the DDS network and drops all dial backup calls
by issuing an sf command and release in the Standby
Facility State field to the control DSU, and an sf
command and release in the Standby Facility State field
command followed by a dial and a q command in the
Number to Dial field to each DBM associated with the
digital bridge. To end the backup session via the SDCP,
address the control DSU and each DBM by issuing the
DrBu (drop backup) command.
Ending the backup session causes the control DSU to
deactivate the bridge, and DSU timing (56 kbps) becomes
the DDS clock source once again. Each DBM-S signals its
tributary that it is dropping the call and hangs up. Each
tributary then switches back to the DDS network, and the
DDS network is again functional. (Between the time that
the bridge is deactivated and the DDS network is
reestablished, errors occur on those tributaries still in
backup.)
Pertinent configuration options for the central-site
bridge, a DBM-S, and tributary DSU-DBMs supporting
the nondisruptive diagnostics configuration. Please note
that all DBM-Ss here should be configured the same –
only the passwords and telephone numbers should differ.
The same holds true for the tributary DSU-DBMs.
Configuration Options
Set the central-site bridge configuration options that
support the nondisruptive diagnostics configuration as
follows (Configuration Worksheet for Bridge Mode):
MUX – Setup
MUX Funct: CBrdg
Bridge Rate: =DSU
Brdg Timing: Auto
Share DevA: Enab
Lowest Port#: DCE
# Ports in Gp: 3
Port Cntrl: Host
Share DevB: Disab
Prt2 and Prt3 (Prt4 through Prt6 N/A)
RTS Cntrl: DTE
Elast Stor: Enab
RTS/CTS Del: 0
DTR Alarm: Disab
DSU
Rate(Kbps): 56
TxClkSource: DDS
Msg Clamp: Enab
TxElastStor: Disab
AggrSwitch: Disab
Diag – DSU
Diag Type: NonD
2nd Ch(bps): 400
Disr Type: Br56
Diag – Gen
Position: Cntrl
LinkConfig: M-Pt
Trib TimOut: enter amount of time
M-Pt SymPrt: Disab
Gen
DTE Port: V.35
Set configuration options for DBM-Ss or DBM-Ds that
support the nondisruptive diagnostics configuration as
follows (Configuration Worksheet for Basic (DBM-V,
DBM-S, or DBM-D) Mode):
Diag – DBM
Diag Type: Disr
RemoteDiag: Enhan
Diag – Gen
Position: Cntrl
LinkConfig: M-Pt
DBM
PrtSp(Kbps): 56
AutoAnswer: Disab
Call Setup: Pswrd
RxPwd: enter received password
TxPwd: enter transmit password
V.13 Signl: Enab
Primary Core: Yes
DTRCallCon: Orig
EchoCancel: Disab
Gen
DTE Port: EIA232
RTS Cntrl: FrcOn
CTS Cntrl: Std
AntiStream: Disab
LSD Lead: Std
CTS Lead: Std
DSR FrcOn: Disab