Set the configuration options for automatic partial
backup of the tributary DSU as follows (Configuration
Worksheet for Basic Mode):
DSU
Rate(Kbps): 9.6
PrtSp(Kbps): 9.6
TxClkSource: DDS
AggrSwitch: Disab
Diag – DSU
Diag Type: Mixed
Disr Type: 3600e
Diag – DBM
Diag Type: Mixed
RemoteDiag: Enhan
Diag – Gen
Position: Trib
LinkConfig: M-Pt
Resp Period: 1
M-Pt SymPrt: Disab
DBM
Rate(Kbps): 9.6
PrtSp(Kbps): 9.6
TxClkSource: RXC
CarrLossDisc: Yes
Auto Retrain: Yes
Single Rate: Yes
AutoAnswer: Enab
TxElasStor: Disab
RxElasStor: Disab
Call Setup: Pswrd
RxPwd: enter received password
TxPwd: enter transmit password
V.13 Signl: Enab
Dial Test: Enab
Primary Core: No
DTRCallCon: Disab
EchoCancel: Disab
Gen
DTE Port: EIA232
RTS Cntrl: DTE
CTS Cntrl: Std
Bkup
Auto Bckup: Enab
Backup Dir: enter Dir number (1 to 10)
BckupOnCMI: Enab
AutoRestor: Enab
NtwkTimOut: enter 1 minute
RestorTimOut: enter 5 minutes
TriesTimOut: enter 1 minute
MultiCall: Disab
LPDA
LPDA-2: Disab
Multipoint Full Dial Backup with
Nondisruptive Diagnostics
The multipoint network in Figure D-6 consists of a
Model 3611 DSU with a digital bridge and two DBM-Ss,
and two a Model 3610 DSUs with Switched 56 DBMs.
Since the DSUs are configured for nondisruptive
diagnostics (Diag Type: NonD), in-band framing is
necessary, and all DSU/DTE interfaces operate at
55600 bps. In addition, it is assumed that the host polls for
all data traffic.
In this scenario, the dial backup process will be
initiated and controlled from the 6800 Series NMS (a
6700 Series NMS can also be used). All tributary DSUs
should be listed in the control DSU’s poll list.
NOTE
For this scenario, DBM-Ss are
used; however, DBM-Ds can
also be used.