Sony DVS-9000 Switch User Manual


 
Chapter 2 Menus and Control Panel
190
Names and Functions of Parts of the Control Panel
the last keyframe. However, if a pause
is set on a keyframe, the effect stops at
that point. Press this button again to
resume execution, and continue to the
next pause point or the end of the
effect.
Effect indicator: This consists of 30 LEDs,
and shows the progress of the effect.
Fader lever: Moving this up or down
manually runs the effect.
REWIND: When this button is pressed, the
currently recalled effect is rewound to
the first keyframe.
FF (fast forward): When this button is
pressed, the currently recalled effect is
advanced to the last keyframe.
h Effect execution direction selection
buttons
NORM (normal): When this button is lit,
effect execution runs from the first
keyframe to the last keyframe.
REV (reverse): When this button is lit,
effect execution runs from the last
keyframe to the first keyframe.
Pressing one of these buttons automatically
turns the other off.
NORM/REV (normal/reverse): Press this
button, turning it on, to reverse the
direction of the effect when it reaches
the last keyframe or first keyframe.
i STOP NEXT KF (stop next
keyframe) button
When this button is pressed, turning it on,
the effect execution range is from the
current time to the next keyframe.
j EFF LOOP (effect loop) button
When the effect reaches the last keyframe
with this button on, it returns to the first
keyframe and repeats.
k AUTO INS (auto insert) button
When editing a macro, press this button,
turning it on, to enable the auto insert
function, so that every control panel
operation you carry out is added to the
macro as an event.