Sun Microsystems X4100 Server User Manual


 
Chapter 4 Maintaining the Sun Fire X4200 Server 4-41
1. Observe the LEDs on the faces of the HDDs and identify the defective HDD:
Middle LED on (amber): The drive is faulty and should be replaced.
Bottom LED on (green): The drive is operating properly.
Note When you replace the HDDs to their bays, you must return each HDD to the
bay from which it was removed. Use an adhesive note or another method to
temporarily label the HDDs when you remove them.
2. Press the button on the face of the HDD to release the spring-loaded securing
latch. See
FIGURE 4-36.
3. Grasp the securing latch and remove the HDD from the drive bay.
FIGURE 4-36 Opening the Hard Disk Drive Latch
Installation is the reverse of this procedure.
TABLE 4-10 Sun Fire X4200 Supported HDD Part Numbers
Component Part Number
36-GB 10K RPM 2.5-inch SAS drive
(RoHS-compliant, replaces 540-6358)
540-6610
73-GB 10K RPM 2.5-inch SAS drive
(RoHS-compliant, replaces 541-0323)
540-6611