E-32 Sun Fire X4100 and Sun Fire X4200 Servers Service Manual • June 2006
E.3.11.2 Create New Array Screen
The Create New Array screen allows you to select disks for a new array. FIGURE E-15
shows this screen. TABLE E-11 describes the fields of the screen.
For an IM volume, when the first disk is added you are asked about the data on the
disks. You have two options:
■ Press M to keep the existing data and migrate to an IM array. Disk
synchronization will occur.
■ Press D to overwrite existing data, and create a new IM array. All data on all disks
in the array will be deleted. No synchronization occurs.
After the volume is configured, press C to create the array. You are asked to save
changes, which will create the array. After the array is created, the utility returns you
to the Adapter Properties screen.
********************************************************************************
* LSI Logic MPT Setup Utility v6.02.00.00 (2005.07.08) *
* Create New Array -- SAS1064 *
* Array Type: IM *
* Array Size(MB): 69618 *
* *
* Scan Device Identifier RAID Hot Drive Pred Size *
* ID Disk Spr Status Fail (MB) *
* 2 FUJITSU MAV2073RCSUN72G 0301 [Yes] [No] Primary --- 70007 *
* 3 FUJITSU MAV2073RCSUN72G 0301 [Yes] [No] Secondary --- 70007 *
* *
* *
* *
* *
* *
* *
* *
* *
* *
* *
* *
* *
* Esc = Exit Menu F1/Shift+1 = Help *
* Space/+/- = Select disk for array or hot spare C = Create array *
*******************************************************************************
FIGURE E-15 Create New Array Screen