Sun Microsystems X4100 Server User Manual


 
Chapter 3 Maintaining the Sun Fire X4100 Server 3-29
3.4.7 Replacing the Front Panel Indicator Board
Follow these steps to remove and replace a front panel indicator board.
Note This component is a CRU and can be replaced by anyone.
TABLE 3-7 lists the qualified part numbers for this component. These part numbers
are subject to change over time. For the most up-to-date list of replaceable
components, product updates, and downloads, see the following URL:
http://www.sun.com/servers/entry/x4100/downloads.jsp
1. Power off the server as described in Section 3.2.1, “Powering Off the Server” on
page 3-2.
2. Remove the main cover as described in Section 3.2.2, “Removing the Main Cover”
on page 3-3.
3. Remove the front bezel as described in Section 3.2.3, “Removing the Front Bezel”
on page 3-4.
Note Always unfasten the bezel’s securing screw before removing the bezel.
4. Remove the front cover as described in Section 3.2.4, “Removing the Front Cover”
on page 3-5.
5. Unfasten the two screws that secure the front panel indicator board to the chassis.
TABLE 3-7 Sun Fire X4100 Supported Front Panel Indicator Board Part Numbers
Component Part Number
Indicator board (front panel) 501-6916