January 2000 © TOSHIBA TEC 1 - 34 -1 FC-22 ADJUSTMENT
Allowable
Operation
Code
Name Default
input value
Contents
procedure
group
1
1
1
1
1
300 0 0-2 0:999 1:99 2:9
302 0-3 0: Off 1: Resettable Copy counter
2: Resettable Original counter
3: Resettable Copy and Original counters
360 0 0-1 RADF reversing of transport belt during
original transporting, to align originals
against the original scale.
0: Disabled 1: Enabled
361 0 0-1 When non-standard originals are used;
0: Non-standard - Machine will stop and
prompt operator to select copy size.
1: Standard - Machine continues the cur-
rent job without stopping
400 Image quality control 1 1 0-1 Auto-performing of image quality control
0: Disabled
1: Enabled (Performing 08-410,413)
Maximum number of copies
allowed
Resettable
1
269 0 0-1 0: Disabled
1: Enabled
Forced performing of image quality
control before the use-level calibration
Copy and Original
counter display
UC: 0
EUR: 3
Switch back
RADF
Non-standard size original
detection
350 Manually placed original 0 0: Not present; 1: Present 1
detection
352 Shooting correction process 0 0: Valid; 2: Invalid 1
setting
353 SALT log table setting 0 0: Normal operation; 1
1: Forced setting on log table
(for ACS/full color);
2: Forced setting on log table
(for single color/monochrome);
3: Forced setting on log table (for CCV)
354 HDEN control 0 0: Normal operation; 1
1: HDEN control operation
355 Sharpness availability setting 1 0: Unavailable; 1: Available 1