FC-22 ADJUSTMENT 1 - 62 January 2000 © TOSHIBA TEC
5. Check if the distance C is within a range of 5±0.5 mm or not.
6. If it is not, change values using the following procedure, and repeat the steps 3. to 5. above.
<Procedure> (Adjustment mode)
(Input code [106] with digital keys)
[START]
(Input a value
(acceptable values : 5 to 251) with digital keys)
[INTERRUPT] (Stored in memory)
* The larger the adjustment value, the shorter the distance C becomes (0.042 mm/
step).
7. When the distance C is within the acceptable range, perform the following procedure.
<Procedure> (Adjustment mode)
(Input code [108] with digital keys)
[START]
(Input a setting
value with digital keys, deducting 47 from the value set in the code [106] adjustment
mode 05)
[INTERRUPT] (Stored in memory)
(f) Secondary-scanning data write start position adjustment (Copier)
1. While pressing the digital keys [0] and [5] simultaneously, turn the power ON.
(Adjustment mode)
2. Place Test Chart No. TCC-1 on the original glass (with the arrow positioned at the left rear side).
3. Press [ENERGY SAVER]
[START] to make a copy in the mode of A4 (LT), 100%, full color and text/
photo.
4. Measure the distance D from the upper paper edge to the upper write-start position on the copy with
a ruler.
5. Check if the distance D is within a range of 5±0.5 mm or not.
6. If it is not, change values using the following procedure, and repeat the steps 3. to 5. above.
* This adjustment should be done for each of the cassettes.
The adjustment order is : 2nd cassette
1st cassette
3rd cassette
4th cassette
Bypass
tray
LCF
ADU.
The adjustment code for each cassette is as follows:
1st cassette : 484 2nd cassette : 485 3rd cassette : 486
4th cassette : 487 Bypass tray : 488 LCF : 489
ADU : 490
<Procedure> (Adjustment mode)
(Input a code [485 to 490] with digital keys)
[START]
(Input
a value (acceptable values : 0 to 15) with digital keys)
[INTERRUPT] (Stored in
memory)
* The larger the adjustment value, the longer the distance D becomes (0.6 mm/step).
(g) Scanner (secondary scanning) start position deviation
1. While pressing the digital keys [0] and [5] simultaneously, turn the power ON.
(Adjustment mode)
2. Place Test Chart No. TCC-1 on the original glass (with the arrow positioned at the left rear side).