FC-22 ADJUSTMENT 1 - 48 January 2000 © TOSHIBA TEC
Ꭾ : Current sensor voltage (V)
Humidity (%) Y M C K
~59.9 3.95~4.05 3.95~4.05 3.95~4.05 3.95~4.05
60.0~74.9 4.09~4.19 4.09~4.19 4.09~4.19 4.07~4.17
75.0~ 4.30~4.40 4.30~4.40 4.30~4.40 4.26~4.36
(10) If an adjustment error occurs, values of the color in problem displayed in A, B or C are replaced with
“
***
”.
As for properly adjusted colors, press the [INTERRUPT] key to store their adjustment results in
memory.
(11) Press the [INTERRUPT] key to store the adjustment results in memory. The screen returns to the
initial display.
100% A A3
[INTERRUPT] ৎ TEST MODE
(12) Remove the developer cartridge(s).
(13) Install the toner cartridge(s).