Toshiba M30-35 Personal Computer User Manual


 
4 Replacement Procedure 4.29 Fluorescent Lamp
2. Assembling PCB-ASSY cell
1) Remove the release paper of the double-sided tape at the upper of the
backlight unit.
2) Light up the backlight.
3) Make sure there is no dust, alien substance or scratch on the backlight. Then
make sure there is nothing wrong with the back of cell, install the PCB-ASSY
cell to the backlight unit.
NOTE: 1) When installing the PCB-ASSY cell, fit it to the left bottom corner of
the backlight unit.
2) Be careful not to damage the TAB.
Cell with PCB
Backlight unit
Fit to the left
bottom corner.
Remove the release
paper of the double-
sided adhesive tape.
Figure 4-57 Replacing TMD fluorescent lamp (WXGA) (7)
4-84 Satellite M30-35 Maintenance Manual (960-455)