Toshiba M30-35 Personal Computer User Manual


 
4.29 Fluorescent Lamp 4 Replacement Procedure
5. Fixing PCBs and bezel with screws
1) Tighten the left side with the screws in order shown in the figure below.
2) Tighten the right side with the screws in order shown in the figure below.
NOTE: 1) Tighten the screws in order. Make sure there is no floating of screw.
2) The screw tightening torque shall be 0.147mN
m (1.5kgf
cm).
3) Use a Philips screwdriver with type 0 bit.
Tighten the eight screws.
(1)
(2)
(3)
(4)
(8)
(7)
(6)
(5)
Figure 4-60 Replacing TMD fluorescent lamp (WXGA) (10)
Satellite M30-35 Maintenance Manual (960-455) 4-87