Uniden UBCD396T Scanner User Manual


 
Search and Close Call Options
107
Off
Srch/CloCall Opt
Max Auto Store
Srch/CloCall Opt
Set Modulation
Auto
AM
FM
NFM
WFM
Srch/CloCall Opt
Set Attenuator
The scanner does not try to find the output
frequency.
This value sets how many hits the scanner will
automatically store when it is in either Search and
Store or Close Call Auto Store mode.
Use the number keys to enter a value from 1 - 256,
then press the scroll control.
When the scanner reaches the maximum number of
hits you set, it stops the auto-store operation.
This setting controls the modulation type used for
quick search and Close Call operations. Select your
setting, then press the scroll control.
Uses the default setting for the current
frequency (see the table at the front of the manual)
Uses AM (amplitude modulation)
Uses FM (frequency modulation)
Uses narrowband FM
Uses wideband FM
Setting the Maximum Auto Store
Value
Setting the Modulation Type
Setting Attenuation