Black Box LEH812 Switch User Manual


 
Black Box Hardened Managed Ethernet Switch
SNMP
SNMP General Setting, SNMP
SNMP General Setting
SNMP Status:
1. Command Mode: Configure mo
Logon to Configure Mode (Configure Term
The switch_a(config)# prompt will show
switch_a(config)#
v1/v2c, SNMP v3
de
inal Mode).
on the screen.
2. Usage:
Use snmp-server enable command to e
command to disable SNMP to the switch.
3. Command Syntax:
(no) snmp-server enable
4. Example:
The following example enables SNMP to the switch:
switch_a(config)#snmp-server enable
switch_a(config)#
nable and no snmp-server enable
Description:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Use snmp-server description command to specify and no snmp-server
description command to remove description for SNMP.
3. Command Syntax:
snmp-server description DESCRIPTION
no snmp-server description
DESCRIPTION The description for SNMP.
4. Example:
The following example specifies description (description) for SNMP:
switch_a(config)#snmp-server description description
switch_a(config)#
User’s Manual 127