Black Box LEH812 Switch User Manual


 
Black Box Hardened Managed Ethernet Switch
The switch_a(config)# prompt will show
switch_a(config)#
on the screen.
2. Usage:
Use snmp-server trap-type enable cold command to enable cold start
trap for SNMP.
Use the no snmp-server trap-type ena
cold start trap for SNMP.
3. Command Syntax:
(no) snmp-server trap-type enable coldStart
4. Example:
The following example enables
switch_a(config)#snmp-server trap-type
switch_a(config)#
Start
ble coldStart command to disable
cold start trap or SNMP: f
enable coldStart
Warm Start Trap:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Use snmp-server trap-type enable warmStart command to enable warm
start trap for SNMP.
Use the no snmp-server trap-type enable warmStart command to disable
warm start trap for SNMP.
3. Command Syntax:
(no) snmp-server trap-type enable warmStart
4. Example:
The following example enables warm start trap for SNMP:
switch_a(config)#snmp-server trap-type enable warmStart
switch_a(config)#
Link Down Trap:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Use snmp-server trap-type enable linkDown command to enable link
130 User’s Manual