User Command Specifications
9.Details of command GET NOSHOW
1
GET NOSHOW
GET NOSHOW
GET□NOSHOW
?△NOSHOW
g
:NOSHOW=<Settin
g
:ID>
For all other responses, refer to "Error List."
-1
A "busy" response is given while the zoom or focus lens is being driven.
(Refer to the ZCONTDRV command and FCONTDRV command.)
-2 The current display screen when nothing is shown can be set by the NOSHOW command.
> GET NOSHOW or ? NOSHOW
< g:NOSHOW=LOGO
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command State
s
OFF ON PM
× ○ ×
× ○ ×
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
This inquiry can be made when the projector is in both the remote mode and power-on status at
the same time.
User screen
ReferenceMode Control Setting
Blue screen
LOGO
Commands
Setting Meaning
BLACK Black screen
01.01** 01.01**
Description
Function
Format
Display screen when nothing is shown setting inquir
y
Response
This inquires about the current setting for the screen to be displayed when nothing is shown.
ID
BLUE
SX50 SX6 SX60 X600
01.01**
○○○○
01.00**
Model Power
Input Mode
Remote Local
Remarks
D-RGB A-RGB1 A-RGB2 Comp Video S-Video D-Video SCART None
SX50
○○○○○○––○○×
SX6
○○○○○○○○○○×
SX60
Example
X600
Command
s
supported
PAGE 109