9Details of command RANGE BRI
1
RANGE BRI
RANGE BRI
RANGEBRI
r:BRI=N, <Minimum setting value>, <Maximum setting value>
-1
A "busy" response is given while the zoom or focus lens is being driven.
-2
> RANGE BRI
< r:BRI=N, -20, 20
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command State
s
OFF ON PM
× ×
× ×
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
Command
s
supported
For all other responses, refer to "Error List."
This inquiry can be made when the projector is in both the remote mode and power-on status
at the same time.
(Refer to the ZCONTDRV command and FCONTDRV command.)
The brightness can be set by the BRI command.
X600
×○○○○○○○
SX6
○○○
SX60
×
SX50
○○○
Remarks
D-RGB A-RGB1 A-RGB2 Comp Video S-Video D-Video SCART None
Model Power
Input Mode
Remote Local
○○○○
01.01**
Brightness setting range reques
t
Mode Control Setting ReferenceCommands
Function
Format
Example
Description
Response
Number
○○○
This inquires about the range of values at which the brightness can be set.
01.00** 01.01** 01.01**