Canon SX60 Projector User Manual


 
User Command Specifications
9Details of command GET LAMPCOUNTER
1
GET LAMPCOUNTER
GET LAMPCOUNTER
GETLAMPCOUNTE
R
?LAMPCOUNTE
R
g
:LAMPCOUNTER="<Lamp ON time: Character strin
g
>
"
For all other responses, refer to "Error List."
-1 This inquiry can be executed in any status provided that AC power is supplied to the projector.
> GET LAMPCOUNTER or ? LAMPCOUNTER
< g:LAMPCOUNTER="[GG______]"
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command State
s
OFF ON PM
× ×
○○○
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
"[GGG_____]"
"[GGGG____]"
"[GGGGG___]"
"[GGGGGY__]"
Meaning (ON time: H)
"[G_______]"
"[GG______]"
"[GGGGGYY_]" 1450
1499
560
839
840
1119
1500
1120
1399
1400
1449
SX50
0 279
280
559
2400
2499
2500
1840
2299
2300
2399
920
1379
1380
1839
SX50
0 459
460
919
1450
1499
1500
1120
1399
1400
1449
560
839
840
1119
SX50
0 279
280
559
1200
1399
1400
599
1000
1199
400
600
800
X600
SX60
○○○○○○○
SX6
○○○
○○×○○○
SX50
○○○
S-Video D-Video SCART None
Mode
Remote Local
Remarks
Model Power
Input
D-RGB A-RGB1 A-RGB2 Comp Video
This inquires about the current lamp ON time.
Lamp ON time
Character
string
SX50
0 199
399
200
999
799
Control Setting
Response
Commands
Function
Format
Lamp ON time inquir
y
Mode Reference
Command
s
supported
Example
SX50 SX6 SX60
01.00** 01.01** 01.01**
Description
For the "SX50," the projector must be in the remote mode and power-on status.
"[GGGGGYYR]"
○○
X600
01.01**
PAGE 121