Canon SX60 Projector User Manual


 
User Command Specifications 9. Details of command TERMINAL
1
TERMINAL
TERMINAL
TERMINAL=<Terminal setting parameter
s
:ID>
Terminal setting parameters
-1
-2
-3
-4
Setting
> TERMINAL=IN This sets to input
< i:OK
Reference
> GET TERMINAL or ?TERMINAL This retrieves the terminal setting state.
< g:TERMINAL=OUT
Acquisition of parameters which can be set
> RANGE TERMINAL
< r:TERMINAL=I, IN, OUT "IN" or "OUT" can be selected as the terminal setting.
* Commands are indicated by ">", and responses are indicated by "<".
When a command is not supported, "e:0002 INVALID_COMMAND" is returned.
Supported Command State
s
OFF ON PM
× ×
× ×
* If the command cannot be supported, 'INVALID_MODE,' 'NOT_POWER_SUPPLIED' or 'TERMINAL_OUT' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
××
Video S-Video
X600
SX50
Model Parameter
SX6
SX60
IN
Power
Input
D-RGB A-RGB1 A-RGB2 NoneD-VideoComp
Function
Parameter
Commands
Paramete
r
Meaning
IN This sets to input
Terminal setting
Format
Example
The current terminal setting can be acquired using the applicable GET command.
SX60 X600
Command
s
supported
×
01.00** 01.01**
The parameters which can be set at any given point in time can be obtained using the
RANGE command.
Remote Local
Mode
SX50 SX6
The “OUT” (output) setting cannot be made when the “A-RGB2” or “COMP” input is selected!
SCART
01.01** 01.01**
Response
For details, refer to the RANGE command.
For all other responses, refer to "Error List."
For details, refer to the GET command.
Description
It can be executed when the projector is in both the remote mode and power-on status at the
same time.
○○○○○○––○○×
OUT ○○××○○––○○×
––––––– ––––––
Reference
ID
This command is identical to the Terminal command in the System settings menu.
"i:OK" is returned if the parameter was set properly.
This sets the input/output of the RGB-IN2/COMPONENT IN/RGB OUT terminals.
This sets to outputOUT
SettingMode
Control