D-Link DES-3550 Switch User Manual


 
150
config dst
e-mth - Configure the month in which DST ends.
<end_mth 1-12> - The month to end DST expressed as a number.
s-time – Configure the time of day to begin DST. Time is expressed
using a 24-hour clock.
e-time - Configure the time of day to end DST. Time is expressed
using a 24-hour clock.
s-date - Configure the specific date (day of the month) to begin DST.
The date is expressed numerically.
e-date - Configure the specific date (day of the month) to begin DST.
The date is expressed numerically.
offset - Indicates number of minutes to add or to subtract during the
summertime. The range of offset are 30,60,90,120; default value is 60
Restrictions Only administrator-level users can issue this command.
Example usage:
To configure daylight savings time on the switch:
DES-3550:4#config dst repeating s_week 2 s_day tue s_mth 4 s_time
15:00 e_week 2 e_day wed e_mth 10 e_time 15:30 offset 30
Command: config dst repeating s_week 2 s_day tue s_mth 4 s_time
15:00 e_week 2 e_day wed e_mth 10 e_time 15:30 offset 30
Success.
DES-3550:4#
show time
Purpose Used to display the current time settings and status.
Syntax
show time
Description This will display system time and date configuration as well as
display current system time.
Parameters None.
Restrictions Only administrator-level users can issue this command.
Example usage:
To show the time cuurently set on the switch’s System clock: