Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEETNEXT
L
TM-U210 series
Specification
(STANDARD)
91 90
• When the printer ID transmission is specified with (65 ≤ n ≤ 69), the following
contents are transmitted:
Header: Hexadecimal = 5FH / Decimal = 95 (1 byte)
Data: Printer information
NUL: Hexadecimal = 00H / Decimal = 0 (1 byte)
After the data is ready to be transmitted, the printer executes the following
process.
➀ Changes READY to BUSY. If it is already BUSY, the printer changes
nothing.
➁ Transmits [Header + Data + NUL].
➂ Executes BUSY to READY. If it is already BUSY from any other cause, the
printer changes nothing.
[Reference] Appendix E
➀
➀➀
➀ GS V m
➁
➁➁
➁ GS V m n
[Name] Feeds paper for cutting position.
[Format]
➀ ASCll GS V m
Hex 1D 56 m
Decimal 29 86 m
➁ ASCll GS V m n
Hex 1D 56 m n
Decimal 29 86 m n
[Range]
➀ m = 1, 49 ➁ m = 66 , 0 ≤ n ≤ 255
[Description] Feeds paper for cutting position as follows:
m Print mode
1, 49 Partial cut (one portion left uncut)
66
Feeds paper for (cutting position +[n × 0.176 mm {1/144 inches}]), and partial
cut.
[Notes] • This command is effective only at the beginning of a line.
• Cutting position differs on each model.
Type A/B: Position of the autocutter
Type D: Position of the manual cutter
[Notes for
①] • Type D model ignores this command.
[Notes for
➁] • When n = 0, the printer feeds the paper to the cutting position.
• When n ≠ 0,the printer feeds the paper to (cutting position +[n × 0.176 mm
{1/144 inches}]).
• Type D model executes the paper feeding only, and does not execute paper
cutting.