Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEETNEXT
L
TM-U210 series
Specification
(STANDARD)
62 61
6.3 Command Descriptions
HT
[Name] Horizontal tab
[Format] ASCII HT
Hex 09
Decimal 10
[Description] Moves the print position to the next horizontal tab position.
[Notes] • This command is valid only when the receive buffer capacity is 40 bytes (when
DIP switch 1-2 is on).
• This command is ignored unless the next horizontal tab position has been set.
• If the next horizontal tab position is outside the printing area, the printing
position shifts to "printing area width + 1."
• Horizontal tab positions are set with ESC D.
• The default tab positions are at intervals of 8 characters (columns 9, 17, 25.) for
font B (7 × 9).
[Reference] ESC D
LF
[Name] Print and line feed
[Format] ASCII LF
Hex 0A
Decimal 10
[Description] Prints the data in the print buffer and feeds one line, based on the current line
spacing.
[Note] This command sets the print position to the beginning of the line.
[Reference] ESC 2, ESC 3