Epson TM-U210 Series Printer User Manual


 
Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEETNEXT
L
TM-U210 series
Specification
(STANDARD)
1314
1 The period from when the remaining space in the receive buffer drops to 16 bytes until
it increases to 32 bytes is called the “buffer full state.”
Data received when the remaining space in the receive buffer is zero bytes is ignored.
2.1.1.4 XON/OFF transmission timing
When XON/OFF control is selected, the printer transmits XON or XOFF signals as follows.
Transmit timing depends on the setting of DIP switch 1-8
Table 2.1.2 XON/XOFF Transmission Timing
DIP Switch 1-8 Status
Printer Status
ON OFF
[XON
transmission]
1) When the printer first goes online after power on or after
resetting through the interface.
Transmission Transmission
2) When the receive buffer is released from the buffer-full state.
Transmission Transmission
3) When the printer status changes from offline to online. ----
Transmission
4) When the printer recovers from an error through a command. ----
Transmission
[XOFF 5) When the receive buffer is full.
Transmission Transmission
transmission] 6) When the printer status changes from online to offline. ----
Transmission
NOTES: The XON code is <11>H and the XOFF code is <13>H.
In case 3), XON is not transmitted when the receive buffer is full.
In case 6), XOFF is not transmitted when the receive buffer is full.
2.1.1.5 Example serial interface connection
Host Printer
TXD-------------------------------------- RXD
DSR ------------------------------------- DTR
CTS-------------------------------------- RTS
RXD ------------------------------------- TXD
DTR-------------------------------------- DSR
FG---------------------------------------- FG
SG --------------------------------------- SG
When connecting the printer to a DCE (DCE: Data Circuit Terminating Equipment), set the
handshaking so that the transmitted data can be received.
Transmit data to the printer after turning on the power and initializing the printer.