Extron electronic 3000B Switch User Manual


 
Exatron 3000B
www.exatron.com 6-19 Chapter 6 Display Dictionary
SHUTTLE EMPTY ?
The handler was expecting a device to be in the shuttle, but none is detected. There has been a miscycle
or a flush cycle.
You may skip past this error by pressing the
[Enter]
button.
You may flush the handler by pressing
[Clear].
SHUTTLE IS LOST
The handler has tried to center the shuttle back to the Home bin, output 5, without success. Press the
[0]
key to turn off the motors. Manually center the shuttle at output 5. Press the
[0]
key again to resume
handler operation.
SHUTTLE OUT JAM
The handler has tried to bin a device. The device is jammed at the output of the shuttle. Manually clear
the jam and the handler will automatically restart. Or you may press the
[Clear]
button to wiggle the output
shuttle and possibly free the jammed device.
Verify that the output tube is not overfilled.
SOLENOID CHECK
Please refer to the Solenoid Diagnostics section in Chapter 5 of this manual.
SORT ERROR
The handler has received an illegal sort command from the tester. The output door LEDs will flash the
received sort. Press the
[Clear]
button on the handler controller keypad to restart operation.
If this message appears frequently, check your tester interface. Please feel free to contact E
XATRON
for
additional assistance. Our toll-free telephone number is 1-800-EXA-TRON.
SORT INPUT
Please refer to the Diagnostics/INTERFACE CHECK: Input Sort section in Chapter 5 of this manual.
SORT MOTOR CHK
Please refer to the Diagnostics/ALL MOTOR CHECK: Shuttle Motor Check section in Chapter 5 of this
manual.
SORT RESET ERR?
The handler has sent a start test pulse out of the Handler Control Port. One or more of the input sorts
remained low. All input sorts must return to logic high within 100 msec of the handler issuing a start test
pulse.
You may turn this check on or off by changing the handler's RAM:
00A5 00 = Sort reset check ON
00A5 FF = Sort reset check OFF
You may press the
[Enter]
button so that the handler will
ISSUE NEW START
. This may reset the input
signals and allow the handler to continue operation. NOTE: Turning off the sort check will allow the
handler to be cycled with an E
XATRON
LED Checker, but it may also cause the handler to missort by using
previous cycle sort information from testers with poor interface controls. We recommend leaving this
check ON.