Exatron 3000B
www.exatron.com 5-10 Chapter 5 Diagnostics
;
;;
;
Solenoid Check
__________________________________________________________________
This diagnostic tests port 03, located on PCB #5000-398, PAL 398-72, U5, U6.
TO ENTER THIS CHECK:
Handler displays
DIAGNOSTICS
Press the
[2]
key.
Handler displays
SOLENOID CHECK
Please refer to the following table. Press each of the handler terminal’s keypad keys
[0]
through
[9]
.
Each key will turn on/off the handler's output cover LEDs and will set the corresponding handler solenoid
into an on/off test cycle. Please refer to Changeover Kit Supplement for specific solenoid information.
Terminal Output Corresponding
Key: Cover LED: Override Switch:
[1]
Solenoid #1 __________ 1
YELLOW BUTTON
[2]
Solenoid #2 __________ 2
WHITE BUTTON
[3]
Solenoid #3 __________ 3
ORANGE BUTTON
[4]
Solenoid #4 __________ 4
BLACK BUTTON
[5]
Solenoid #5 __________ 5
GREEN BUTTON
[6]
Solenoid #6 __________ 6
GREY BUTTON
[7]
Solenoid #7 __________ 7
RED BUTTON
[8]
Solenoid #8 __________ 8
BLUE BUTTON
[9]
All Solenoids ON ALL On
[0]
All Solenoids OFF ALL Off
Pressing the
[Clear]
button will flash the terminal's displayed message to confirm the handler is still in this
specific diagnostic check.
Press the
[Enter]
button to EXIT this diagnostic check and return to the
DIAGNOSTICS