Exatron 3000B
www.exatron.com 2-14 Chapter 2 Installation
Practice session: Cycling sample devices
1. Upon completion of all Handler Diagnostics sequences, turn the handler power off, then on again.
When the handler controller displays
MOD SET UP ? NO
, press the
[SET UP]
button to toggle this
message to
MOD SET UP ? YS
.
2. Make all necessary Set Up Modifications as detailed in Chapter 4, Handler Set Up.
3. Locate a sample set of devices and tubes to use for practice.
4. An Exatron LED Checker, part #3000-052, may be used as a simulator to run sample devices through
the handler. In this case, select the Handler Port Interface during Set Up Modification and switch the
Sort Select Pin 1 to the ON position. This will simulate the tester/programmer. A sort select of 1 will
force all parts cycled to binned to a PASS tube.
LED CHECKER
5. Run the sample devices until you are comfortable with the operation of the Model 3000B handler. You
are now ready to interface the handler to your tester or PROM programmer. Please refer to Chapter 3
Interface Information for details on communications interface selection.