Extron electronic 3000B Switch User Manual


 
Exatron 3000B
www.exatron.com 4-11 Chapter 4 Handler Setup
ADRS DESCRIPTION ROM RAM
OPTIONS
COMMENTS
00D6 Plunge Steps 10 4 30 to 39 For Plunge to Board Type 4 Changeover Kits. Sets the
10s digit of the Z-motor plunge to contact steps. Set as
ASCII Number.
00D7 Plunge Steps 1 6 30 to 39 For Plunge to Board Type 4 Changeover Kits. Sets the
1s digit of the Z-motor plunge to contact steps. Set as
ASCII Number.
00D8 2
nd
Start Width 00 00 to FF Sets the width of an available second start pulse to be
used in the event that the tester has a problem with the
handler’s standard start pulse timing. Use this 2
nd
Start
feature only to solve interface problems flagged by the
error messages, “SORT NOT RESET” and/or “MULTI
SORT ERROR.” S
EE
I
NTERFACE
C
HAPTER FOR FURTHER
DETAILS
.
00D9 2
nd
Start Delay 00 00 to FF Sets a time delay before the handler sends an available
second start pulse to the tester. Counts down in HEX in
1 millisecond steps. The second start pulse feature is
used in the event that the tester has a problem with the
handler’s standard start pulse timing. Use this 2
nd
Start
feature only to solve interface problems flagged by the
error messages, “SORT NOT RESET” and/or “MULTI
SORT ERROR.” S
EE
I
NTERFACE
C
HAPTER FOR FURTHER
DETAILS
.
00DA Soak Time 1.0 S 0 30 to 39 Sets a per test cycle “Soak Delay” for Model 3010 Hot
Rails Sets 1.0 second digit.
00DB Soak Time 0.1 S 0 30 to 39 Sets a per test cycle “Soak Delay” for Model 3010 Hot
Rails Sets 0.1 second digit.
00DC
Label Size 04 00 to 06 Sets default label size
01 = 300 DIP
02 = 600 DIP
03 = 20 PLCC
04 = 28/32 PLCC
05 = 44 PLCC
06 = 5 x 7 LCC
00DD 300 DIP V Delay 06 00, 30 Sets label print to vacuum on delay for 3000BL
00DE 600 DIP V Delay 20 00, 30 Sets label print to vacuum on delay for 3000BL
00DF 20 PLCC V Delay 0A 00, 30 Sets label print to vacuum on delay for 3000BL
00E0 28/32 V Delay 15 00, 30 Sets label print to vacuum on delay for 3000BL
00E1 44 PLCC V Delay 19 00, 30 Sets label print to vacuum on delay for 3000BL
00E2 5 x 7 V Delay 10 00, 30 Sets label print to vacuum on delay for 3000BL
00E3 FF
00E4 FF
00E5 5B Electronics FF 5B, FF Sets the handler to do self tests on handlers equipped
with Type 5B electronics, (Extra RS-232 port)
FF = No 5B checks
00E6 Pickup 10000 0 30 to 39 For Type 5B CO Kits only
Sets 10000’s digit, Home sensor to pick up point