www.exatron.com 4-10 Chapter 4 Handler Setup
ADRS DESCRIPTION ROM RAM
OPTIONS
COMMENTS
00BF FF
00C0 Sort 1 Bins 1-8 EF 00 to FF Input Sort 1 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.
00C1 Sort 2 Bins 1-8 10 00 to FF Input Sort 2 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.
00C2 Sort 3 Bins 1-8 10 00 to FF Input Sort 3 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.
00C3 Sort 4 Bins 1-8 10 00 to FF Input Sort 4 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.
00C4 Sort 5 Bins 1-8 10 00 to FF Input Sort 5 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.
00C5 Sort 6 Bins 1-8 10 00 to FF Input Sort 6 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.
00C6 Sort 7 Bins 1-8 10 00 to FF Input Sort 7 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.
00C7 Sort 8 Bins 1-8 10 00 to FF Input Sort 8 to handler output bins. BIT MAP.
Output cover LEDs will blink output Bin locations.
00C8 Pick Up Step
1000
1 30 to 39 Label Pick up “1000” step setting 3000BL only
00C9 Pick Up Step 100 0 30 to 39 Label Pick up “100” step setting 3000BL only
00CA
Pick Up Step 10 1 30 to 39 Label Pick up “10” step setting 3000BL only
00CB Pick Up Step 1 2 30 to 39 Label Pick up “1” step setting 3000BL only
00CC
Apply Step 100 4 30 to 39 Label Apply “100” step setting 3000BL only
00CD
Apply Step 10 3 30 to 39 Label Apply “10” step setting 3000BL only
00CE Apply Step 1 7 30 to 39 Label Apply “1” step setting 3000BL only
00CF Label Que 01 00 to 19 Sets the number of labels printed on power up. Setting
depends on version of 3000BL. In most cases set to 01,
prints only 1 label. 3000BL only
00D0 Add Label FF 00, AA,
FF
For 3000BL only
00 = Test and Label in one operation
FF = Test only, skip the label site
AA = Label only, no test
00D1 Bit Check 00 00, FF For P
ROGRAMMER
RS-232 Interface only.
Performs Illegal Bit Test at the start of the programming
cycle.
00 = Bit Check ON. (Data I/O)
FF = Bit Check OFF. (Bytek)
00D2 Interface Type 26 23, 25,
26
Sets default interface to be used by the handler.
23 = P
ROGRAM
RS-232 Interface (Data I/O, Bytek)
25 = E
XATRON
RS-232 Interface
26 = H
ANDLER
P
ORT
Interface
00D3 P/V/L 02 02, 04,
08
For P
ROGRAMMER
RS-232 Interface only.
Selects Program, Verify, or Load Master operation.
02 = Program. 04 = Verify. 08 = Load Master.
00D4 Plunge
Steps1000
0 30 to 39 For Plunge to Board Type 4 Changeover Kits. Sets the
1000s digit of the Z-motor plunge to contact steps. Set
as ASCII Number.
00D5 Plunge Steps 100 3 30 to 39 For Plunge to Board Type 4 Changeover Kits. Sets the
100s digit of the Z-motor plunge to contact steps. Set
as ASCII Number.