Extron electronic 3000B Switch User Manual


 
Exatron 3000B
www.exatron.com 3-15 Chapter 3 Interface Info
RS-232 Interfaces
EXATRON SUPER ~ EXATRON RS-232 ~ H P RS-232 ~ PROGRAMMER RS-232
RS-232 Port Options:
Listed below are addresses in the handler's battery backed-up RAM which may be edited to fine tune
the handler for your specific programmer/tester and sorting requirements. These addresses are not
part of the standard power-up selections and
may be modified only by “Changing The RAM,”
as
described in the Handler Set-Up Chapter of this manual.
B
AUD
R
ATE
009A __
This address stores the baud rate setting for the RS-232 serial port. The RS-232
port uses the 25 pin RS-232 connector on the side of the handler.
009A 06
19200 Baud
009A 0C 9600 Baud [Default setting]
009A 18
4800 Baud
009A 30
2400 Baud
009A 60
1200 Baud
009A C0
600 Baud
009A 80
300 Baud
D
ATA
F
ORMAT
009B __
This address stores the data format setting for the RS-232 port.
009B 02
No parity 7 Data 1 Stop
009B 2A
Stick one 7 Data 1 Stop
009B 3A
Stick zero 7 Data 1 Stop
009B 1A
Even parity 7 Data 1 Stop
009B 0A
Odd parity 7 Data 1 Stop
009B 06
No parity 7 Data 2 Stop
009B 2E
Stick one 7 Data 2 Stop
009B 3E
Stick zero 7 Data 2 Stop
009B 1E
Even parity 7 Data 2 Stop
009B 0E
Odd parity 7 Data 2 Stop
009B 03 No parity 8 Data 1 Stop [Default setting]
009B 2B
Stick one 8 Data 1 Stop
009B 3B
Stick zero 8 Data 1 Stop
009B 1B
Even parity 8 Data 1 Stop
009B 0B
Odd parity 8 Data 1 Stop
009B 07
No parity 8 Data 2 Stop
009B 2F
Stick one 8 Data 2 Stop
009B 3F
Stick zero 8 Data 2 Stop
009B 1F
Even parity 8 Data 2 Stop
009B 0F
Odd parity 8 Data 2 Stop