Extron electronic 3000B Switch User Manual


 
Exatron 3000B
www.exatron.com 4-9 Chapter 4 Handler Setup
ADRS DESCRIPTION ROM RAM
OPTIONS
COMMENTS
00B3 FF
00B4 Gate Closed
Delay
02 00, FF Delay to allow gate to close on PLCC Type 4 CO kits.
Counts down in HEX in 10 msec steps
00B5 L Apply Delay 0A 00, FF Adds a delay after the label has been detected by the
vacuum on the label pick up head. Time to allow the
label to be fully picked up by the pick up head.
Counts down in Hex in 10 msec steps.
00B6 Shuttle Delay 10 00 to FF Delays shuttle solenoid being turned off after device has
exited the shuttle into the output tube. Allows more time
for device to completely exit the shuttle.
Counts down in HEX in 10 msec steps.
00B7 FF
00B8 XTAL SMD Size 00 00 turns this option off
For Type 5B CO Kits Only, XTAL Devices only
50 = Sets the handler to run CA devices
51 = Sets the handler to run JA devices
52 = Sets the handler to run JC devices
00B9 Label Yes/No 00 Turns on all of the label apply software. Handler must
be a 3000BL.
00 = Turns label option OFF
01 = Turns label option on, label Sort 1 only
02 = Turns label option on, label Sort 2 only
….08, Sort/Label apply HEX decode
00BA Label Out Delay 05 Adds delay to DUT exiting the label site, more time for
the stop pin to remain open. For 3000BL handlers only
00BB Stop-Fail Sort FE 00 to FF Tells the handler which sort(s) to stop the system upon
Fail from tester.
00 = No stop on fail
FE = Stop on fail, all sorts EXCEPT bin 1
02 = Stop on fail, sort 2 only
00BC Double Test Sort 00 00 to FF Tells the handler which test sorts to double test if
desired.
00 = Double Test is OFF for all sorts.
FE = Double Tests all sorts except Sort 1
02 = Double test sort 2 only
00BD Send H on Retest FF 00, AA,
FF
Sets the handler to send the ASCII character “H” to the
tester at the start of each retest cycle, as it does at the
start of each first test cycle to establish communication.
This may be used for certain device count applications.
FF = Send H on test, send H on retest
00 = Send H on test, none on retest
AA = Never send H test or retest
00BE SOL Shut Down 00 00, FF 00 = Handler will automatically shut off all solenoids
after 30 seconds of inactivity. Recommended for
handlers using solenoids in their CO Kits. Will prevent
some “melt downs”.
FF = Handler will leave Solenoids in active state until the
operator intervenes.