ADRS DESCRIPTION ROM RAM
OPTIONS
COMMENTS
00FA Soft Full/Half 02 00, 02 Sets the Z-motor to use full (0.006”) steps, or half
(0.003”) steps in this special reduced-impact plunger
sequence. 00 = Full step setting; 02 = Half step setting.
For Type 4 Plunge to Board CO Kits Only
00FB Up Steps 100 0 30 to 39 Sets 100’s Digit on Self Adjust Z on Type 4 Plunge to
board CO Kits
00FC Up Steps 10 2 30 to 39 Sets 10’s Digit on Self Adjust Z on Type 4 Plunge to
board CO Kits
00FD Up Steps 1 1 30 to 39 Sets 1’s Digit on Self Adjust Z on Type 4 Plunge to
board CO Kits
00FE Self Adj Z Extra 2 30 to 34 This feature provides from 0 to 4 additional Up steps to
the Self Adjust Z-Motor sequence on Plunge to Board
Changeover kits. Creates a slightly larger gap so the
device under test can more easily slide under the pick
up head. Set as ASCII number.
For Type 4 Plunge to Board CO Kits Only
00FF FF