Fujitsu MB86617A Network Card User Manual


 
LSI Specification
MB86617A
Rev.1.0 Fujitsu VLSI
64
BIT Bit Name Action Value Function
0 Indicates that CIP header of received Isochronous packet is normal.
1 Rx CIP err-A Read
1
Indicates that CIP header of received Isochronous packet has an error.
Clears to 0 by lead of this register.
0
Indicates that FMT range of CIP header of received Isochronous packet is the value
allowed to be received at DV-EN, DSS-EN or TS-EN (1Ch bit10 to 8)
(DV=00000, MPEG2=10000 or DSS=100001).
0 Rx FMT err-A Read
1
Indicates that FMT range of CIP header of received Isochronous packet is other
than the value allowed to be received at DV-EN, DSS-EN or TS-EN (1Ch bit10 to
8) (DV=00000, MPEG2=10000 or DSS=100001).
Clears to 0 by reading of this register.