Auto Enable
Determines the initial state of the LAPB circuit.
The LAPB-specific Auto Enable parameter works in conjunction with the global Auto
Enable parameter based on the following criteria:
When global Auto Enable is No, the LAPB circuit identified by Circuit Name is
unconditionally disabled—the LAPB-specific Auto Enable parameter is disabled
when the global Auto Enable parameter is disabled.
When global Auto Enable is Yes, the LAPB circuit is conditionally enabled—the
LAPB-specific Auto Enable parameter can be enabled or disabled when global Auto
Enable is enabled.
Default: Yes
Yes
Automatically enables the LAPB circuit when the global Auto Enable parameter is
enabled.
No
Automatically disables the LAPB circuit when the global Auto Enable parameter is
enabled. (Then, to enable the circuit after the router boots, use the NCL Interpreter’s
Enable command.)
Note: The LAPB-specific Auto Enable parameter should be set to an applicable setting
regardless if the global Auto Enable parameter is enabled. If the global Auto Enable
parameter is later enabled, the current setting for the LAPB-specific Auto Enable
parameter takes effect.
Broadcast
Identifies IP Address as a possible recipient of broadcast messages.
Yes
X.25 forwards broadcast messages to IP Address.
No
X.25 does not forward broadcast messages.
Call Retry Timer (secs)
Sets the interval between call request packets to a specific destination. In the event of
an unsuccessful call attempt (for example, the call request is cleared), the router
waits Call Retry Timer (secs) before sending another call request to the destination.
Any IP datagrams received for the destination during this period are dropped by the
router.
X.25 Service Parameters
Parameters and Options
13-4