Invalid MFS, dflt=2
Meaning: The configuration record for circuit: cct contains a faulty value in the
Minimum Frame Spacing field. The system has defaulted to a value of 2.
Action: Modify Minimum Frame Spacing in the configuration.
Invalid N2, dflt=16
Meaning: The configuration record for circuit: cct contains a faulty value in the
Retry Counter (N2) field. The system has defaulted to a value of 16.
Action: Modify Retry Counter (N2) in the configuration.
Invalid QOS. Setting to LLC1
Meaning: The Quality of Service parameter was not configured as LLC1
(unreliable datagram). Presently LLC1 is the only quality of service
supported for frame relay. Therefore, the Quality of Service parameter
has been automatically modified to be LLC1.
Action: Modify the configuration so that the Quality of Service parameter is
LLC1.
Invalid shift parameter
XXX
Meaning: A management packet was received with an unrecognizable shifting
parameter. This applies only to those interfaces running ANSI Annex D.
All information elements must be encoded using locking shift 5. Any
other shifting parameters will be flagged as an error and data following
will be discarded.
Invalid STATUS message received
Meaning: For the indicated frame relay circuit, the status message returned from
the frame relay switch is not properly formatted. That is, the report type
and keep-alive sequence exchange messages were not found in the
proper order.
Event Log
Messages
17
Event Log Messages
cct: Circuit Event Messages