data_rx contains the number of DATA packets received by X.25
circuit cct.
DATA packets contain user data.
data_tx contains the number of DATA packets transmitted by X.25
circuit cct. DATA packets contain user data.
dropped_tx contains the count of IP datagrams dropped by the
circuit because of X.25 failures or queue clipping.
error_rx contains the number of erroneous packets (for example,
packets with a bad length, REGISTRATION packets if registration is not
enabled, and RESTART packets not directed to LCN0) received by X.25
circuit cct.
reset_cfm_rx contains the number of RESET CONFIRMATION
packets received by X.25 circuit cct. A RESET CONFIRMATION packet
acknowledges that the previously requested reset action has been
implemented.
reset_cfm_tx contains the number of RESET CONFIRMATION
packets transmitted by X.25 circuit cct. A RESET CONFIRMATION
packet acknowledges that the previously requested reset action has
been implemented.
reset_rx contains the number of RESET INDICATION packets
received by X.25 circuit cct. A RESET INDICATION packet informs the
recipient that the remote node has reset the send and receive packet
sequences to 0.
reset_tx contains the number of RESET REQUEST packets trans-
mitted by X.25 circuit cct. A
RESET REQUEST packet sets the send and
receive packet sequences to 0, and generates a RESET INDICATION
packet at the remote end of the circuit.
restart_cfm_rx contains the number of RESTART CONFIRMATION
packets received by X.25 circuit cct. A
RESTART CONFIRMATION packet
acknowledges that the previously requested restart action has been
implemented.
restart_cfm_tx contains the number of RESTART CONFIRMATION
packets transmitted by X.25 circuit cct. A RESTART CONFIRMATION
Management Information Base Variables