HP (Hewlett-Packard) 400 Network Router User Manual


 
o_sent Indicates the number of octets sent from this circuit since it
was created.
exmib.fr.ccttbl.entry.o_sent.cct #.ddd
36.26.2.1.7cct #.ddd
where cct # indicates the circuit and ddd indicates the dlci.
state Indicates whether the particular circuit is operational. These
entries are created by the Data Link Connection Management exchange.
There are three possible values for this entry:
Invalid (1) is used to delete an entry manually.
Active (2) is an indication that the circuit is up and ready for
use.
Inactive (3) is used to show that the circuit is present but not
ready for use.
exmib.fr.ccttbl.entry.state.cct #.ddd
36.26.2.1.3.cct #.ddd
where cct # indicates the circuit and ddd indicates the dlci.
Frame Relay Error Table Variables
This table describes errors encountered on the Frame Relay interface. It
is indexed by circuit number. The error table variables, in alphabetical
order, are as follows:
data Is an octet string containing as much of the error packet as
possible. As a minimum, it must contain the two octets of the DLCI.
exmib.fr.errtbl.entry.data.cct #
36.26.3.1.3.cct #
where cct # indicates the circuit.
index Is the index into the error table that corresponds to the circuit
number.
exmib.fr.errtbl.entry.index.cct #
36.26.3.1.1.cct #
where cct # indicates the circuit.
Managment
Information Base
18
Management Information Base Variables
cct: Circuits Information Base
18-29