TCP/IP Configuration 31
Table 3.2 describes parameters that may be included in the TFTP
configuration file.
Table 3.2 TFTP Configuration File Parameters (1 of 3)
ews-config: Enables or disables the embedded web server on the HP
JetDirect print server. To enable, set to 1. To disable, set
to 0.
idle-timeout: The number of seconds that an idle print data connection
is allowed to remain open. Since the card supports only
a single TCP connection, the idle timeout balances the
opportunity of a host to recover or complete a print job
against the ability of other hosts to access the printer.
The acceptable values range from 0 to 3600 (1 hour). If
“0” is typed, the timeout mechanism is disabled. The
default is 90 seconds.
allow: netnum
[mask]
Provides an entry into the host access list stored on the
HP JetDirect print server. Each entry specifies a host or
network of hosts that are allowed to connect to the
printer. The format is “allow: netnum [mask]” where
netnum is a network number or host IP address, and
mask is an address mask of bits applied to the network
number and host address to verify access. Up to 10
access list entries are allowed. If there are no entries, all
hosts are permitted access. For example:
allow: 10.0.0.0 255.0.0.0 allows hosts on network 10.
allow: 15.1.2.3 allows a single host. In this case, the
default mask 255.255.255.255 is assumed and is not
required.
tcp-mss: Specifies the maximum segment size (MSS) that the HP
JetDirect print server will advertise for use when
communicating with local subnets (MSS=1460 bytes or
more) or remote subnets (MSS=536 bytes):
0 (default) All networks are assumed to be local
(MSS=1460 bytes or more).
1 Use MSS=1460 bytes (or more) for subnets, and
MSS=536 bytes for remote networks.
2 All networks are assumed to be remote (MSS=536
bytes), except the local subnet.
location: Identifies the physical location of the printer (SNMP
sysLocation object). Only printable ASCII characters are
allowed. The maximum length is 64 characters. The
default location is undefined. (Example:
1st floor,
south wall
)