TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-142 August 9, 2005
K
a
a
aw
s
k
ERROR CODE E6012 Relative distance between guns is too near.
The gun tips of two networked robots is less than the minimum specified distance for the
application.
⇒
If this error occurs in teach mode, drive the axes so the distance between gun tips is
within specified value.
⇒
If this error occurs in check/repeat mode,
modify the program data, and change the
motion timing and relative distance.
If this error does not occur in a near-miss condition,
check the distance (and home position) set for error de-
tection for the robot pair.
_____________________________________________________________________
ERROR CODE E6500 No welding interface board.
The welding interface (1GN) board is not detected at control power ON.
⇒
Turn control power off and confirm that the welding interface (1GN) board is mounted
to the 1GW (1HW) board
.
⇒
Confirm that the welding interface (1GN) board is not loose. Insert the board firmly.
⇒
Replace the 1GW/1GN (1HW/1GN) board.
_____________________________________________________________________
ERROR CODE E6501 No. 2 welding interface board not found.
The polarity ratio function is set for analog output, or an additional 1GW (1HW) board is
required for 3, or more, analog output channels.
⇒
Install additional 1GW (1HW) board as required
.
⇒
Ensure 1GW (1HW) boards are properly installed.
_____________________________________________________________________
NOTE