Kawasaki MPVDCONTV113E-3 Robotics User Manual


 
TROUBLESHOOTING
1-177August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
K
a
a
aw
s
k
ERROR CODE P1024 Statement cannot be executed.
Occurs when the AS Language instruction entered is not acceptable for the mode of
operation.
Example: DO HOME is executed with TEACH LOCK ON.
Use instructions and commands that are compatible with the selected mode.
_____________________________________________________________________
ERROR CODE P1025 Cannot be executed, function not set.
An attempt is made to use a function that is not installed or set-up.
Example: Communication with 1GV board with data communication or I/O communica-
tion disabled.
To add a function that is not set-up or installed contact KRI customer service
.
Example: For the above example, enable data communication or I/O communication.
_____________________________________________________________________
ERROR CODE P1026 Can’t KILL program that is running.
Displayed when an attempt is made to KILL a program that is executing.
Stop program execution with HOLD or ABORT commands before program is removed
from the stack with a KILL command.
_____________________________________________________________________
ERROR CODE P1027 Cannot edit program, TEACH LOCK is ON.
Programs cannot be edited if the TEACH LOCK switch is ON.
Turn TEACH LOCK switch OFF.
_____________________________________________________________________
ERROR CODE P1028 Cannot paste.
Occurs when the operator is executing the paste function and no data is stored in the
paste buffer or the step(s) cannot be overwritten.
Ensure steps are copied before paste operation is executed.
Ensure insertion point is correct or steps can be overwritten.
_____________________________________________________________________