Kawasaki MPVDCONTV113E-3 Robotics User Manual


 
TROUBLESHOOTING
1-179August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
K
a
a
aw
s
k
ERROR CODE P1034 This program is not editable.
The auto load measurement program cannot be edited.
Use a program name that does not include the auto load measurement program
name.
_____________________________________________________________________
ERROR CODE P1035 Record inhibited. Set [record accept] and operate again.
Displayed when an attempt is made to enter data, but Inhibit Record in auxiliary function
0802 is set to inhibit.
Change the setting of the Inhibit Record in AUX 0802.
_____________________________________________________________________
ERROR CODE P1036 Program change inhibited. Set [Accept] and operate
again.
Displayed when an attempt is made to enter data, but Program Change in auxiliary
function 0802 is set to inhibit.
Change the setting of the Program Change in AUX 0802.
_____________________________________________________________________
ERROR CODE P1037 Program name cannot be called “calib_load_”.
Use a program name that does not include
“calib_load_
“.
_____________________________________________________________________
ERROR CODE P1038 Program does not exist.
Main causes include:
1. Non-existing program is selected.
2. Program check operation or cycle start is executed without a program selected.
Select an existing program before executing program check or cycle start.
_____________________________________________________________________