ERROR CODE P1034 This program is not editable.
The auto load measurement program cannot be edited.
⇒
Use a program name that does not include the auto load measurement program
name.
_____________________________________________________________________
ERROR CODE P1035 Record inhibited. Set [record accept] and operate again.
Displayed when an attempt is made to enter data, but Inhibit Record in auxiliary function
0802 is set to inhibit.
⇒
Change the setting of the Inhibit Record in AUX 0802.
_____________________________________________________________________
ERROR CODE P1036 Program change inhibited. Set [Accept] and operate
again.
Displayed when an attempt is made to enter data, but Program Change in auxiliary
function 0802 is set to inhibit.
⇒
Change the setting of the Program Change in AUX 0802.
_____________________________________________________________________
ERROR CODE P1037 Program name cannot be called “calib_load_”.
⇒
Use a program name that does not include
“calib_load_
“.
_____________________________________________________________________
ERROR CODE P1038 Program does not exist.
Main causes include:
1. Non-existing program is selected.
2. Program check operation or cycle start is executed without a program selected.
⇒
Select an existing program before executing program check or cycle start.