Mitsubishi Electronics Q64TCRTN Network Card User Manual


 
301
CHAPTER 6 VARIOUS SETTINGS
6
6.3 Parameter Setting
Integral time (I) setting Page 107, Section 3.4.2 (16)
Derivative time (D) setting Page 107, Section 3.4.2 (17)
Control output cycle setting/Heating control output cycle setting Page 114, Section 3.4.2 (23)
Control response parameter Page 116, Section 3.4.2 (25)
Stop Mode Setting Page 103, Section 3.4.2 (13)
PID continuation flag Page 131, Section 3.4.2 (43)
Forward/reverse action setting Page 121, Section 3.4.2 (30)
Upper limit setting limiter
Page 122, Section 3.4.2 (31)
Lower limit setting limiter
Setting change rate limiter or Setting change rate limiter (Temperature rise)
Page 119, Section 3.4.2 (28)
Setting change rate limiter (Temperature drop)
Sensor correction value setting Page 113, Section 3.4.2 (21)
Number of moving averaging Page 151, Section 3.4.2 (72)
Primary delay digital filter setting Page 115, Section 3.4.2 (24)
Upper limit output limiter/Heating upper limit output limiter
Page 110, Section 3.4.2 (19)
Lower limit output limiter
Output variation limiter Page 112, Section 3.4.2 (20)
Adjustment sensitivity (dead band) setting Page 113, Section 3.4.2 (22)
Self-tuning setting Page 146, Section 3.4.2 (68)
Temperature conversion setting Page 150, Section 3.4.2 (71)
Cooling method setting Page 151, Section 3.4.2 (73)
Cooling upper limit output limiter Page 110, Section 3.4.2 (19)
Cooling control output cycle setting Page 114, Section 3.4.2 (23)
Overlap/dead band setting Page 152, Section 3.4.2 (74)
Process value (PV) scaling function enable/disable setting Page 152, Section 3.4.2 (76)
Process value (PV) scaling lower limit value
Page 153, Section 3.4.2 (77)
Process value (PV) scaling upper limit value
Derivative action selection Page 153, Section 3.4.2 (79)
Simultaneous temperature rise group setting Page 154, Section 3.4.2 (80)
Simultaneous temperature rise AT mode selection Page 155, Section 3.4.2 (83)
Setting change rate limiter Unit time setting Page 157, Section 3.4.2 (85)
Peak current suppression control group setting Page 158, Section 3.4.2 (86)
Automatic backup setting after auto tuning of PID constants Page 128, Section 3.4.2 (37)
Cold junction temperature compensation selection Page 135, Section 3.4.2 (49)
Alert 1 to 4 mode setting Page 137, Section 3.4.2 (52)
Alert set value 1 to 4 Page 108, Section 3.4.2 (18)
Alert dead band setting Page 129, Section 3.4.2 (38)
Number of alert delay Page 129, Section 3.4.2 (39)
Loop disconnection detection judgment time Page 124, Section 3.4.2 (33)
Loop disconnection detection dead band Page 125, Section 3.4.2 (34)
Heater disconnection alert setting Page 123, Section 3.4.2 (32)
Heater disconnection/output off-time current error detection delay count Page 130, Section 3.4.2 (40)
Heater disconnection compensation function selection Page 131, Section 3.4.2 (44)
AT Bias Page 120, Section 3.4.2 (29)
Auto tuning mode selection Page 136, Section 3.4.2 (51)
During AT loop disconnection detection function enable/disable setting Page 145, Section 3.4.2 (66)
Temperature rise completion range setting Page 130, Section 3.4.2 (41)
Setting item Reference