388
CH Sensor correction value setting Un\G45 Un\G77 Un\G109 Un\G141 Page 113, Section 3.4.2 (21)
CH Adjustment sensitivity (dead band)
setting
Un\G46 Un\G78 Un\G110 Un\G142 Page 113, Section 3.4.2 (22)
CH Control output cycle setting Un\G47 Un\G79 Un\G111 Un\G143 Page 114, Section 3.4.2 (23)
CH Primary delay digital filter setting Un\G48 Un\G80 Un\G112 Un\G144 Page 115, Section 3.4.2 (24)
CH Control response parameters Un\G49 Un\G81 Un\G113 Un\G145 Page 116, Section 3.4.2 (25)
CH AUTO/MAN mode shift Un\G50 Un\G82 Un\G114 Un\G146 Page 117, Section 3.4.2 (26)
CH MAN output setting Un\G51 Un\G83 Un\G115 Un\G147 Page 118, Section 3.4.2 (27)
CH Setting change rate limiter/Setting
change rate limiter (temperature rise)
Un\G52 Un\G84 Un\G116 Un\G148 Page 119, Section 3.4.2 (28)
CH AT bias Un\G53 Un\G85 Un\G117 Un\G149 Page 120, Section 3.4.2 (29)
CH Forward/reverse action setting Un\G54 Un\G86 Un\G118 Un\G150 Page 121, Section 3.4.2 (30)
CH Upper limit setting limiter Un\G55 Un\G87 Un\G119 Un\G151
Page 122, Section 3.4.2 (31)
CH Lower limit setting limiter Un\G56 Un\G88 Un\G120 Un\G152
CH Heater disconnection alert setting Un\G58 Un\G90 Un\G122 Un\G154 Page 123, Section 3.4.2 (32)
CH Loop disconnection detection
judgment time
Un\G59 Un\G91 Un\G123 Un\G155 Page 124, Section 3.4.2 (33)
CH Loop disconnection detection dead
band
Un\G60 Un\G92 Un\G124 Un\G156 Page 125, Section 3.4.2 (34)
CH Unused channel setting Un\G61 Un\G93 Un\G125 Un\G157 Page 126, Section 3.4.2 (35)
CH E
2
PROM's PID constants read
instruction
Un\G62 Un\G94 Un\G126 Un\G158 Page 127, Section 3.4.2 (36)
CH Automatic backup setting after auto
tuning of PID constants
Un\G63 Un\G95 Un\G127 Un\G159 Page 128, Section 3.4.2 (37)
CH Alert dead band setting Un\G164 Page 129, Section 3.4.2 (38)
CH Number of alert delay Un\G165 Page 129, Section 3.4.2 (39)
CH Heater disconnection/output off-
time current error detection delay count
Un\G166 Page 130, Section 3.4.2 (40)
CH Temperature rise completion range
setting
Un\G167 Page 130, Section 3.4.2 (41)
CH Temperature rise completion soak
time setting
Un\G168 Page 131, Section 3.4.2 (42)
CH PID continuation flag Un\G169 Page 131, Section 3.4.2 (43)
CH Heater disconnection compensation
function selection
Un\G170 Page 131, Section 3.4.2 (44)
CH Transistor output monitor ON delay
time setting
Un\G175 Page 132, Section 3.4.2 (45)
CH CT monitor method switching Un\G176 Page 132, Section 3.4.2 (46)
CH Resolution of the manipulated value
for output with another analog module
Un\G181 Page 134, Section 3.4.2 (48)
CH Cold junction temperature
compensation selection
Un\G182 Page 135, Section 3.4.2 (49)
CH Auto tuning mode selection Un\G184 Un\G185 Un\G186 Un\G187 Page 136, Section 3.4.2 (51)
CH Alert 1 mode setting Un\G192 Un\G208 Un\G224 Un\G240
Page 137, Section 3.4.2 (52)
CH Alert 2 mode setting Un\G193 Un\G209 Un\G225 Un\G241
CH Alert 3 mode setting Un\G194 Un\G210 Un\G226 Un\G242
CH Alert 4 mode setting Un\G195 Un\G211 Un\G227 Un\G243
CT CT input channel assignment
setting
Un\G264 to Un\G271 (set for each current sensor (CT)) Page 139, Section 3.4.2 (54)
Buffer memory area name
Buffer memory address
Reference
CH1 CH2 CH3 CH4