Pacific Digital RI-310e Power Supply User Manual


 
Pacific Research Solutions RI-300e User Manual
Page 158
DEFAULT MACRO DATA
Start line 001 067C 340C D System reset, power on
Start line 002 010C D System off
Start line 003 011C D System on, COS access
Start line 004 013C D System on, CTCSS/DCS + COS
Start line 005 014C D System on, open squelch
Start line 006 18011C D Repeater DTMF mute on
Start line 007 18010C D Repeater DTMF mute off
Start line 008 0430C D Carrier delay on
Start line 009 040C D Carrier delay off
Start line 010 222C D PL Encode on
Start line 011 220C D PL Encode off
Start line 012 061C 821C 065C 1510C D Telephone off-hook
Start line 013 067C 820C 1511C D Telephone on-hook
Start line 014 80C D Flash Hook
Start line 015 061C 829C 1510C D Answer a ringing telephone
Start line 016 343C 35111C A1343C A135111C D Link on
Start line 018 340C A1340 C D Link off
Start line 019 31 039 079 118 279 C D Message, Normal courtesy
Start line 020 31 027 079 165 282 C D Message, Weak signal courtesy
Start line 021 30 166 393 485 C D Message, Power on reset courtesy “RST”
Start line 022 31 053 079 165 118 272 326 130 290 C D Message, Post timeout
Start line 024 31 118 043 079 294 039 294 C D Message, Pre timeout
Start line 025 30 617 217 C D Message, Function error “ERROR”
Start line 026 31 041 079 118 324 216 246 242 C D Message, Function acknowledgment “OK”
Start line 028 31 118 089 049 326 272 316 055 316 049 Message, Auto patch ring
316 055 316 055 316 049 316 055 280 C D
Start line 031 31 118 099 043 304 C D Message, 10 Second test tone @1KHz
Start line 032 31 118 079 049 272 318 271 310 039 282 C D Message, Un-lock courtesy
Start line 034 30 005 429 214 571 216 169 C D Message, Auto patch answer message “HELLO”
Start line 035 30 005 617 077 073 C D Message, Auto patch function ack. “OK"
Start line 036 30 005 617 217 C D Message, Auto patch function “ERROR”
Start line 037 31 005 027 078 165 295.C D Message, Auto patch ring back
Start line 038 31 036 079 118 212 239 236 243 243 246 C D Message, Station ID "HELLO"
Start line 040 through 049 Next available line
Start line 050 061C 131100C D Vertex Low TX Power, approximately 10 watts
Start line 051 061C 65481001#480901C 6853C DD Check for over temp and battery operation
Start line 053 061C 131200C D Vertex High TX Power, approximately 25 watts
Start line 054 061C 46110C D TX LED on
Start line 055 061C 46111C D TX LED off
Start line 056 061C 46121C 46130C 6850C D BATT LED on, AC LED off jump to Low power
Start line 057 061C 46120C 46130C 6851C D BATT LED off, AC LED on jump to High power
Start line 058 061C 46121C 46130C 6853C D BATT LED on, AC LED off jump to High power
Start line 059 660C 4509056C 4510151C 6863C D AC initialization, enable triggers and jump to line 63
Start line 061 660C 4509058C 4510153C 6863C D DC initialization, enable triggers and jump to line 63
Start line 063 4509157C 4510050C 4527154C Finish Vertex initialization.
Start line 064 4527055C 661C D